- Home
- Catalogue
- USS - Ultrasound
- USS - High Level Disinfection Supplies
- APT - Apparel & Linen Supplies
- AWM - Airway Management
- CAR - Cardiology
- CLN - Cleaners & Detergents
- CON - Contrast & Accessories
- CRS - Cleaning Room Supplies
- CUP - Cups
- DIA - Diabetes Management
- DIS - Disinfectant & Supplies
- ERD - Exam Room Disposables
- ERE - Exam Room Equipment
- FER - Fertility Clinic Supplies
- FIT - Fitness at Home
- FLM - Cassettes & Holders
- FUR - Furniture
- GLV - Gloves
- INF - Infection Control
- LBL - Labels , Signs & Printers
- LMP - Lighting
- MAM - Mammography
- MDS - Medical Supplies
- MRK - Markers
- NUC - Nuclear Medicine
- OPT - Ophthalmology
- PER - Personal Care
- PHA - Phantoms
- PHY - Physiotherapy
- POS - Positioning Aids
- RAD - Radiation Protection
- REP - Reporting Equipment
- SED - Sleep Dentistry
- USS - Ultrasound
- WMA - Waste Management
- WRS - Washroom Supplies
USS - High Level Disinfection Supplies

Test Strip Revital-Ox Resert
Manufacturer: |
Steris Corporation 109827 |
Catalogue Number: |
DIS-PCC054 |
A chemical indicator designed exclusively to determine whether hydrogen peroxide, the active ingredient in RESERT High Level Disinfectant Solutions, is above the minimum recommended concentration (MRC) of 1.5%. RESERT High-Level Disinfectant solutions should be tested before each usage in order to guard against dilution, which may lower the hydrogen peroxide concentration of the solution below its MRC of 1.5% hydrogen peroxide.
Initially after a test strip is immersed in the RESERT Solution for two seconds and removed, the solution will turn the original blue color of the test strip to a uniform yellow. At the same time, hydrogen peroxide reacts with potassium iodide/starch in the test strip to develop to a uniform black color over a 90 second (1½ minute) period (passing). When the solution is below its MRC, the test strip will show non-uniform areas of black and yellow colors (failing).

Cleaner Enzyclean EBL-1HC
Manufacturer: |
Weiman Products |
Catalogue Number: |
CLN-EBL1HC |
Specially formulated for use in washing equipment and for safe manual use. Used for effectively and safely cleaning glass, plastic, rubber and metal surgical instruments and equipment. Provides one step cleaning of delicate fiberoptic equipment. It leaves instruments moving freely and spot-free. It is designed to be used on instrumentation immediately following the surgical procedure. Minimizes instrument handling, thus reducing exposure to potentially infectious organic contaminants. It ensures the thorough and complete cleaning of equipment and instruments, a prerequisite to the completion of the decontamination process. The enzyme in this detergent quickly disintegrates organic soils in hard to reach areas, including lumens, channels and box locks. The enzyme breaks down (actually digests) the organic soils, and the detergent removes them completely, holding them in suspension and avoiding redepositing on the cleaned surfaces

Wipes Disinfectant Accel PREVention
Manufacturer: |
Diversey Inc. |
Catalogue Number: |
DIS-100906721 |
Tuberculocidal, Virucidal, Bactericidal, Fungicial broad-spectrum sanitizer.
- A ready-to-use pre-wetted disinfectant cleaner wipe based on AHP technology
- Overall contact time, 3 minutes
- Environmentally friendly - active ingredient breaks down into oxygen and hydrogen
- 6 X 7" wipes, 160 sheets per tub, 12 tubs per case

Test Strip 2% AHP PREempt HLD5
Manufacturer: |
Virox Technologies Inc 129834 |
Catalogue Number: |
DIS-AHP2 |
Accelerated Hydrogen Peroxide (AHP) Indicator Test Strips are easy to use dip-and-read reagent strips for a pass or fail determination of hydrogen peroxide concentration in AHP disinfectant solutions for variety of applications.
Dip the strip into the test solution for one second, making sure that the reagent pad is fully wet. Gently shake off the excess solution. Wait for 60 seconds then compare the colour on the reagent pad with the reference colour block. If the colour on the reagent pad is lighter than the reference colour block for a “PASS”, then the concentration of hydrogen peroxide is below the minimum recommended concentration for the AHP solution and should be discarded. “FAIL” colour blocks are provided only for reference and should not be used for measuring or quantifying the level of hydrogen peroxide in the AHP solution.

Kit for Endocavity Disinfection RESERT
Manufacturer: |
|
Catalogue Number: |
USS-DISINFX-RESERT |
Do you have all the accessories and supplies you need to disinfect your endocavity probes?
Here is a startup kit for 1-2 endocavity probes that would meet all the requirements.
- Soaking Cups - 2
- Alcohol-free disinfecting wipes - 6 tubs
- Enzymatic Wash concentrate - 2 jugs
- AHP-based high level disinfectants - 4 jugs RESERT HLD
- Test Strips for AHP disinfectants - 2 packs RESERT test strips
- Polybags to cover cleaned endocavity probees - 1000 ea of 2 X 8" polybag
Optional add-ons
- Timer
- Nitrile Gloves
- Isolaiton gowns
- Protective Eyewear
- Faucet-mounted eye wash
- Lint-free J-Cloth dry wipes

Kit for Endocavity Disinfection PREempt
Manufacturer: |
|
Catalogue Number: |
USS-DISINFX-PREEMPT |
Do you have all the accessories and supplies you need to disinfect your endocavity probes?
Here is a startup kit for 1-2 endocavity probes that would meet all the requirements.
- Soaking Cups - 2
- Alcohol-free disinfecting wipes - 6 tubs
- Enzymatic Wash concentrate - 2 jugs
- AHP-based high level disinfectants - 4 jugs PREempt HLD
- Test Strips for AHP disinfectants - 2 packs PREempt test strips
- Polybags to cover cleaned endocavity probees - 1000 ea of 2 X 8" polybag
Optional add-ons
- Timer
- Nitrile Gloves
- Isolaiton gowns
- Protective Eyewear
- Faucet-mounted eye wash
- Lint-free J-Cloth dry wipes

Disinfectant Soaking PREempt HLD5
Manufacturer: |
Virox Technologies Inc 129834 |
Catalogue Number: |
DIS-11505 |
A high level disinfectant and sterilant for processing heat sensitive semi-critical and critical medical devices and instruments for which heat sterilization is not suitable. The exceptional safety profile means there is no special ventilation required. PREempt HLD5’s active Hydrogen Peroxide is environmentally preferable (breaks down into water and oxygen, leaving no active ingredient residue).
5-minute high level disinfection 14-day reusable solution
- Designed for use on heat sensitive semi-critical & critical devices.
- Virucidal: 5 Min., Poliovirus, Sabin strain type 1, which allows for a Broad-Spectrum Virucide claim against most enveloped and non-enveloped viruses
- Bactericidal: 5 Min.
- Fungicidal: 5 Min.
- Tuberculocidal: 5 Min
- Sporicidal: 6 Hrs. • Bacillus subtilis • Clostridium sporogenes
- Test Strips Available (AHP2)

Disinfectant Soaking Revital-Ox™ Resert® HLD
Manufacturer: |
Steris Corporation 109827 |
Catalogue Number: |
DIS-4440AWCA |
Resert High Level Disinfectant - Chemosterilant is a RTU reusable high level disinfectant for processing heat sensitive, semi-critical medical devices. Resert HLD is an oxidative chemistry, using 2% Accelerated Hydrogen Peroxide (AHP), eliminating staff and patient exposure hazards associated with aldehyde-based HLD solutions.
- Kills HPV virus.
- No extra ventilation required • Leaves no toxic residues on devices • No patient contraindications, contact dermatitis or respiratory distress
- One rinse, saving time and water • 5-minute contact time • Re-useable for up to 14 days
- Formulated with biodegradable ingredients • Requires no detoxification – pours safely down the drain • Single rinse requires less water than other high-level disinfectants • No heating required for activation

Polybag Clear 2 Mil Sealed End 2" X 8"
Manufacturer: |
|
Catalogue Number: |
MDS-S1994 |
- Inexpensive polybags to cover clean transvaginal probes
- Meets FDA and USDA specifications for food contact.
- 100% virgin, high clarity polyethylene film
- Latex free
- Sulfur free, Amine and Silicon free, BHT free (Butylated Hydroxy Toluene), Chlorine free, Acid free
- Water-resistant not waterproof.
- Archival safe

Polybag Clear 2 Mil Sealed End 3" X 10"
Manufacturer: |
|
Catalogue Number: |
MDS-S1428 |
- Inexpensive polybags to cover clean transvaginal probes
- Meets FDA and USDA specifications for food contact.
- 100% virgin, high clarity polyethylene film
- Latex free
- Sulfur free, Amine and Silicon free, BHT free (Butylated Hydroxy Toluene), Chlorine free, Acid free
- Water-resistant not waterproof.
- Archival safe
- 3" X 10" Flat
Timer Digital DT122
Manufacturer: |
|
Catalogue Number: |
MDS-DT122 |
- Jumbo LCD display
- 99 minutes & 59 seconds maximum time setting
- Count down timer
- 30 second beeper alarm
- Memory recalls previous time setting
- Magnetic back, built-in clip, retractable stand